Model | SV-60-12 | SV-60-24 | SV-60-48 | |
Output | DC Voltage | 12V | 24V | 48V |
Voltage Tolerance | ±2% | ±1.5% | ±1.5% | |
Rated Current | 5A | 2.5A | 1.25A | |
Current Range | 0~5A | 0~2.57A | 0~1.25A | |
Rated Power | 60W | 60W | 60W | |
Ripple & Noise | 50mVp-p | 50mVp-p | 100mVp-p | |
Voltage ADJ. range | 10.8~13.2V | 21.6~26.4V | 43.2~52.8V | |
Setup,rise time | 200ms,30ms/230VAC (at full load) | |||
Hold up time | 100ms/230VAC (at full load) | |||
Input | Voltage Range | 90-132V or 180~264VAC, 255~370VDC | ||
Frequency | 47~63HZ | |||
AC Current | 1.4A/115VAC 0.8A/230VAC | |||
Efficiency | 80% | 81% | 82% | |
Inrush Current | Cold start 30A/230VAC | |||
Leakage Current | < 3.5mA/240VAC | |||
Protection | Overload | Rated output power 105%~150% start over load protection | ||
protection type:Constant current limiting, recovers automatically after fault condition is removed. | ||||
Environment | Working temp., humidity | -10℃~+60℃, 20%~90%RH non-condensing | ||
Storage temp., humidity | -20℃~+85℃, 10%~95%RH | |||
Temp. Coefficient | ±0.03%/℃(0~45℃) | |||
Withstand Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min., each along X, Y, Z axes | |||
Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
Isolated Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH | |||
Compliance | Safety Standard | Compliance to UL1012 | ||
EMC Standard | Compliance to EN55022, Class B, EN61000-6-1 | |||
Others | Dimension | 190x48x34mm(LxWxH) | ||
Weight/packing | 0.53kg/28pcs/15kg | |||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |