Model | SE-600-12 | SE-600-15 | SE-600-24 | SE-600-36 | SE-35-48 | |
Output | DC Voltage | 12V | 15V | 24V | 36V | 48V |
Voltage Tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated Current | 50A | 40A | 25A | 16.7A | 12.5A | |
Current Range | 0~50A | 0~40A | 0~25A | 0~16.7A | 0~12.5A | |
Rated Power | 600W | 600W | 600W | 600W | 600W | |
Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 180mVp-p | 200mVp-p | |
Voltage ADJ. range | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | 32.4~39.6V | 43.2~52.8V | |
Setup,rise time | 1.5s,50ms/230VAC | |||||
Hold up time | 20ms/230VAC 16ms/115VAC (at full load) | |||||
Input | Voltage Range | 90~132VAC or 180~264VAC, 255~370VDC | ||||
Frequency | 47~63HZ | |||||
AC Current | 6.5A/230VAC | |||||
Efficiency | 81% | 82% | 86% | 86% | 87% | |
Inrush Current | Cold start 50A/230VAC | |||||
Leakage Current | < 3.5mA/240VAC | |||||
Protection | Overload | Rated output power 105%~150% start over load protection | ||||
protection type:Constant current limiting, recovers automatically after fault condition is removed. | ||||||
Overvoltage | Protection type:Shut down o/p voltage,recovers automatically after fault condition is removed | |||||
Overtemp | Protection type:Output voltage decline,recovers automatically after temperature fall | |||||
Environment | Working temp., humidity | -10℃~+60℃, 20%~90%RH non-condensing | ||||
Storage temp., humidity | -20℃~+85℃, 10%~95%RH | |||||
Temp. Coefficient | ±0.03%/℃(0~45℃) | |||||
Withstand Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min., each along X, Y, Z axes | |||||
Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
Isolated Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH | |||||
Compliance | Safety Standard | Compliance to UL1012 | ||||
EMC Standard | Compliance to EN55022, Class B, EN61000-6-1 | |||||
Others | Dimension | 241x124x65mm(LxWxH) | ||||
Weight/packing | 1.3kg/12pcs/16kg | |||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |