Model | S-60-5 | S-60-12 | S-60-24 | S-60-48 | |||||
Output | DC Voltage | 5V | 12V | 24V | 48V | ||||
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% | |||||
Rated Current | 12A | 5A | 2.5A | 1.25A | |||||
Current Range | 0~12A | 0~5A | 0~2.5A | 0~1.25A | |||||
Rated Power | 60W | 60W | 60W | 60W | |||||
Ripple & Noise | 75mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | |||||
Voltage ADJ. range | 4.75~5.5V | 10.8~13.2V | 21.6~26.4V | 43.2~52.8V | |||||
Setup,rise time | 100ms,30ms/230VAC 200ms,30ms/115VAC(at full load) | ||||||||
Hold up time | 30ms/230VAC 10ms/115VAC (at full load) | ||||||||
Input | Voltage Range | 90~132VAC/180~264VAC selected by switch, 255~370VDC | |||||||
Frequency | 47~63HZ | ||||||||
AC Current | 1.4A/115VAC 0.8A/230VAC | ||||||||
Efficiency | 75% | 80% | 84% | 84% | |||||
Inrush Current | Cold start 36A/230VAC 18A/115VAC | ||||||||
Leakage Current | < 3mA/240VAC | ||||||||
Protection | Overload | Rated output power 105%~150% start over load protection | |||||||
protection type:Constant current limiting, recovers automatically after fault condition is removed. | |||||||||
Environment | Working temp., humidity | -10℃~+60℃, 20%~90%RH non-condensing | |||||||
Storage temp., humidity | -20℃~+85℃, 10%~95%RH | ||||||||
Temp. Coefficient | ±0.03%/℃(0~45℃) | ||||||||
Withstand Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min., each along X, Y, Z axes | ||||||||
Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||
Isolated Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||||||
Compliance | Safety Standard | Compliance to UL1012 | |||||||
EMC Standard | Compliance to EN55022, Class B, EN61000-6-1 | ||||||||
Others | Dimension | 159x97x38mm(LxWxH) | |||||||
Weight/packing | 0.38kg/30pcs/11.8kg | ||||||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |