Model | S-1500-12 | S-1500-15 | S-1500-24 | S-1500-36 | S-1500-48 | ||
Output | DC Voltage | 12V | 15V | 24V | 36V | 48V | |
Voltage Tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ||
Rated Current | 125A | 100A | 62.5A | 55.6A | 31.3A | ||
Current Range | 0~125A | 0~100A | 0~62.5A | 0~55.6A | 0~31.3A | ||
Rated Power | 1500W | 1500W | 1500W | 1500W | 1500W | ||
Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | ||
Voltage ADJ. range | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | 32.4~39.6V | 43.2~52.8V | ||
Setup,rise time | 1500ms,50ms/230VAC | ||||||
Hold up time | 20ms/230VAC (at full load) | ||||||
Input | Voltage Range | 180~264VAC, 255~370VDC | |||||
Frequency | 47~63HZ | ||||||
AC Current | 17A/230VAC | ||||||
Efficiency | 85% | 86% | 86% | 85% | 87% | ||
Inrush Current | Cold start 60A/230VAC | ||||||
Leakage Current | < 3.5mA/240VAC | ||||||
Function | Fan on/off control | RTH2.RTH3 ≥55℃ FAN ON,≤50℃ FAN OFF | |||||
Protection | Overload | Rated output power 105%~150% start over load protection | |||||
protection type:Shut down o/p voltage,re-power on to recover | |||||||
Overvoltage | Protection type:Shut down o/p voltage, re-power on to recover | ||||||
Overtemp | Protection type:Shut down o/p voltage, recovers automatically after temperature fall | ||||||
Environment | Working temp., humidity | -10℃~+60℃, 20%~90%RH non-condensing | |||||
Storage temp., humidity | -20℃~+85℃, 10%~95%RH | ||||||
Temp. Coefficient | ±0.03%/℃(0~45℃) | ||||||
Withstand Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min., each along X, Y, Z axes | ||||||
Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolated Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||||
Compliance | Safety Standard | Compliance to UL1012 | |||||
EMC Standard | Compliance to EN55022, Class B, EN61000-6-1 | ||||||
Others | Dimension | 291x132x68mm(LxWxH) | |||||
Weight/packing | 3.0kg/6pcs/18.5kg | ||||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |