LRS - Ultra Thin Power Supply

LRS-35W

Port:
China
Payment Terms:
T/T
Model:
LRS-35 Series
Brand
CNDF / OEM
Code
8504.40
Contact Now
Model LRS-35-5 LRS-35-12 LRS-35-15 LRS-35-24 LRS-35-36 LRS-35-48
Output DC voltage 5V 12V 15V 24V 36V 48V
Rated current 7A 3A 2.4A 1.5A 1A 0.8A
Current range 0~7A 0~3A 0~2.4A 0~1.5A 0~1A 0~0.8A
Rated power 35W 36W 36W 36W 36W 38.4W
Ripple&noise 100mVp-p 120mVp-p 120mVp-p 150mVp-p 200mVp-p 200mVp-p
DC voltage ADJ. range ±10% ±10% ±10% ±10% ±10% ±10%
Voltage tolerance ±3% ±2% ±1% ±1% ±1% ±1%
Line regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load regulation ±2% ±1% ±0.5% ±0.5% ±0.5% ±0.5%
Setup,rise,hold up time 800ms,30ms,30ms/230VAC(full load)
Input Voltage range 90~264VAC,127~373VDC
Frequency range 47~63HZ
AC current 0.7A/115VAC 0.42A/230VAC
Inrush current Cold start 45A/230VAC
Efficiency 83% 86% 87% 88% 89% 90%
Leakage current <0.75mA/240VAC
Protection overload Rated output power110%~150% start over load protection
protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage Rated output voltage 115%~135% Start over voltage protection
Protection type:hiccup mode,auto-recovery after fault condition is removed
Environment Working temp,
humidity
-30℃~+70℃(Please refer to“derating curve”)
20%~90%RH Non-condensing
Storage temp,
humidity
-40℃~+85℃,10%~95%RH non-condensing
Withstand vibration 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes
Safety Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation resistance I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
Fit standard Safety standards Compliance to UL60950-1,TUV EN60950-1,GB4943
EMC emission Compliance to EN55022(CISPR22)Class B,GB9254 Class B,EN55014,EN61000-3-2,3
EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1
Others Dimension 99*82*30mm(L*W*H)
Weight/packing 0.23kg/60pcs/14.8kg/0.025m³/0.88CUFT
MTBF ≥720K hrs min. MIL-HDBK-217F(25℃)
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation is measured from 0% to 100% rated load
6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft)
7.The power supply is considered as a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.
Feedback
Related Products
E-seal Sanitary Butterfly Valve Rotary Encoder Bolt seal manufacturers