LRS - Ultra Thin Power Supply

LRS-200W

Port:
China
Payment Terms:
T/T
Model:
LRS-200 Series
Brand
CNDF / OEM
Code
8504.40
Contact Now
Model LRS-200-5 LRS-200-12 LRS-200-15 LRS-200-24 LRS-200-36 LRS-200-48
Output DC voltage 5V 12V 15V 24V 36V 48V
Rated current 40A 17A 14A 8.8A 5.9A 4.4A
Current range 0~40A 0~17A 0~14A 0~8.8A 0~5.9A 0~4.4A
Rated power 200W 204W 210W 211.2W 212.4W 211.2W
Ripple&noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
DC voltage ADJ. range ±10% ±10% ±10% ±10% ±10% ±10%
Voltage tolerance ±3% ±2% ±1% ±1% ±1% ±1%
Line regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load regulation ±2% ±1% ±0.5% ±0.5% ±0.5% ±0.5%
Setup,rise,hold up time 800ms,50ms,16ms/230VAC(full load)
Input Voltage range 90~132VAC/180~264VAC(selected by switch),240~373VDC
Frequency range 47~63HZ
AC current 4.0A/115VAC 2.2A/230VAC
Inrush current Cold start 50A/230VAC
Efficiency 85% 87% 88% 89% 89% 90%
Leakage current <2mA/240VAC
Protection overload Rated output power110%~140% start over load protection
protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage Rated output voltage 115%~135% Start over voltage protection
Protection type:hiccup mode,auto-recovery after fault condition is removed
Environment Over temperature 100℃±10℃(RTH3 detect beside magnetic core)
Protection type:cut off the output,auto-recovery after the temperature become normal
Working temp,humidity -25℃~+70℃(Please refer to“derating curve”)
20%~90%RH Non-condensing
Safety Storage temp,humidity -40℃~+85℃,10%~95%RH non-condensing
Withstand vibration 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes
Fit standard Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation resistance I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
Safety standards Compliance to UL60950-1,TUV EN60950-1,GB4943
Others EMC emission Compliance to EN55022(CISPR22)Class B,GB9254 Class B,EN55014,EN61000-3-2,3
EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1
Dimension 215*115*30mm(L*W*H)
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation is measured from 0% to 100% rated load
6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft)
7.The power supply is considered as a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.
Feedback