Model | LRS-150-5 | LRS-150-12 | LRS-150-15 | LRS-150-24 | LRS-150-36 | LRS-150-48 | |
Output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated current | 20A | 12.5A | 10A | 6.5A | 4.3A | 3.3A | |
Current range | 0~20A | 0~12.5A | 0~10A | 0~6.5A | 0~4.3A | 0~3.3A | |
Rated power | 120W | 150W | 150W | 156W | 154.8W | 158.4W | |
Ripple&noise | 120mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
DC voltage ADJ. range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage toleranceNote.3 | ±3% | ±2% | ±1% | ±1% | ±1% | ±1% | |
Line regulationNote.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulationNote.5 | ±2% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup,rise,hold up time | 800ms,30ms,40ms/230VAC(full load) | ||||||
Input | Voltage range | 90~132VAC/170~264VAC(selected by switch),240~373VDC | |||||
Frequency range | 47~63HZ | ||||||
AC current | 2.8A/115VAC 1.6A/230VAC | ||||||
Inrush current | Cold start 50A/230VAC | ||||||
Efficiency | 84.50% | 87% | 88% | 88% | 89% | 90% | |
Leakage current | <0.75mA/240VAC | ||||||
Protection | overload | Rated output power110%~150% start over load protection | |||||
protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over voltage | Rated output voltage 115%~135% Start over voltage protection | ||||||
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Environment | Over temperature | 100℃±10℃(RT1 detect beside transformer) | |||||
Protection type:cut off the output,auto-recovery after the temperature become normal | |||||||
Working temp,humidity | -30℃~+70℃(Please refer to“derating curve”) | ||||||
20%~90%RH Non-condensing | |||||||
Safety | Storage temp,humidity | -40℃~+85℃,10%~95%RH non-condensing | |||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | ||||||
Fit standard | Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Safety standards | Compliance to UL60950-1,TUV EN60950-1,GB4943 | ||||||
Others | EMC emission | Compliance to EN55022(CISPR22)Class B,GB9254 Class B,EN55014,EN61000-3-2,3 | |||||
EMC immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1 | ||||||
Dimension | 159*97*30mm(L*W*H) | ||||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 0% to 100% rated load 6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft) 7.The power supply is considered as a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives. |