DR-60W

Port:
China
Payment Terms:
T/T
Model:
DR-60 Series
Brand
CNDF / OEM
Code
8504.40
Contact Now
Model DR-60-12 DR-60-15 DR-60-24 DR-60-48
Output DC Voltage 12V 15V 24V 48V
Voltage Tolerance ±1% ±1% ±1% ±1%
Rated Current 5A 4A 2.5A 1.25A
Current Range 0~5A 0~4A 0~2.5A 0~1.25A
Rated Power 60W 60W 60W 60W
Ripple & Noise 100mVp-p 100mVp-p 100mVp-p 100mVp-p
Voltage ADJ. range 10.8~13.2V 13.5~16.5V 21.6~26.4V 43.2~52.8V
Setup,rise time 200ms,30ms/230VAC (at full load)
Hold up time 50ms/230VAC (at full load)
Input Voltage Range 90-264VAC ,127-370VDC
Frequency 47~63HZ
AC Current 1.4A/115VAC 0.8A/230VAC
Efficiency 80% 80% 82% 82%
Inrush Current Cold start 36A/230VAC 18A/115VAC
Leakage Current < 3.5mA/240VAC
Protection Overload Rated output power 105%~150% start over load protection
protection type:Constant current limiting, recovers automatically after fault condition is removed.
Over voltage Protection type:Output voltage decline, recovers automatically after fault condition is removed
Environment Working temp., humidity -10℃~+60℃, 20%~90%RH non-condensing
Storage temp., humidity -20℃~+85℃, 10%~95%RH
Temp. Coefficient ±0.03%/℃(0~45℃)
Withstand Vibration 10~500Hz, 2G 10min./1cycle, period for 60min., each along X, Y, Z axes
Safety Withstand Voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH
Compliance Safety Standard Compliance to UL1012
EMC Standard Compliance to EN55022, Class B, EN61000-6-1
Others Dimension 78x93x56mm(LxWxH)
Weight/packing 0.25kg/60pcs/15.2kg
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
Feedback