DR - DIN Rail Power Supply

DR-480W

Port:
China
Payment Terms:
T/T
Model:
DR-480 Series
Brand
CNDF / OEM
Code
8504.40
Contact Now
Model DR-480-12 DR-480-15 DR-480-24 DR-480-48
Output DC Voltage 12V 15V 24V 48V
Voltage Tolerance ±1% ±1% ±1% ±1%
Rated Current 24A 32A 20A 10A
Current Range 0~24A 0~32A 0~20A 0~10A
Rated Power 480W 480W 480W 480W
Ripple & Noise 100mVp-p 100mVp-p 100mVp-p 150mVp-p
Voltage ADJ. range 10.8~13.2V 13.5~16.5V 21.6~26.4V 43.2~52.8V
Setup,rise time 200ms,20ms/230VAC (at full load)
Hold up time 20ms/230VAC (at full load)
Input Voltage Range 180-264VAC ,255-370VDC
Frequency 47~63HZ
AC Current 5.5A/230VAC
Efficiency 85% 84% 85% 86%
Inrush Current Cold start 40A/230VAC 20A/115VAC
Leakage Current < 3.5mA/240VAC
Protection Overload Rated output power 105%~150% start over load protection
protection type:Constant current limiting, recovers automatically after fault condition is removed.
Over voltage Protection type:Output voltage decline, recovers automatically after fault condition is removed
Environment Working temp., humidity -10℃~+60℃, 20%~90%RH non-condensing
Storage temp., humidity -20℃~+85℃, 10%~95%RH
Temp. Coefficient ±0.03%/℃(0~45℃)
Withstand Vibration 10~500Hz, 2G 10min./1cycle, period for 60min., each along X, Y, Z axes
Safety Withstand Voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH
Compliance Safety Standard Compliance to UL1012
EMC Standard Compliance to EN55022, Class B, EN61000-6-1
Others Dimension 125.2x125.2x100mm(LxWxH)
Weight/packing 1.1kg/12pcs/13.4kg
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
Feedback
Related Products
E-seal Sanitary Butterfly Valve Rotary Encoder Bolt seal manufacturers